Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the viwec-email-template-customizer domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/ritsasv.com/html/wp-includes/functions.php on line 6121

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the quiz-maker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/ritsasv.com/html/wp-includes/functions.php on line 6121

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the jetpack domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/ritsasv.com/html/wp-includes/functions.php on line 6121

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wpforms-lite domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/ritsasv.com/html/wp-includes/functions.php on line 6121

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wordpress-seo domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/ritsasv.com/html/wp-includes/functions.php on line 6121

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/ritsasv.com/html/wp-includes/functions.php on line 6121

Deprecated: Function is_staging_site is deprecated since version 3.3.0! Use in_safe_mode instead. in /var/www/ritsasv.com/html/wp-includes/functions.php on line 6121
MQ-2 MQ-3 MQ-4 MQ-5 MQ-6 MQ-7 MQ-8 MQ-9 MQ-135 Detection Smoke methane liquefied Gas Sensor Module for Arduino Starter DIY Kit -
Deprecated: Function is_staging_site is deprecated since version 3.3.0! Use in_safe_mode instead. in /var/www/ritsasv.com/html/wp-includes/functions.php on line 6121
, ,

MQ-2 MQ-3 MQ-4 MQ-5 MQ-6 MQ-7 MQ-8 MQ-9 MQ-135 Detection Smoke methane liquefied Gas Sensor Module for Arduino Starter DIY Kit

Price range: $10.00 through $12.00

SKU: 3256805157140772 Categories: , ,

MQ-2 Sensor

  • Model: MQ-2

  • Gas: smoke

  • Detection range: 300 to 10000ppmm

  • Characteristic gas: 1000ppmm isobutane

  • Sensitivity: R in air/Rin typical gasge5

  • Sensitive body resistance: 1KOmega to 20KOmega in 50ppm toluene

  • Response time: le10s

  • Recovery time: le30s

  • Heating resistance: 31 Omega plusmn 3 Omega

  • Heating current: le180mA

  • Heating voltage: 5.0V plusmn 0.2V

  • Heating power: le900mW

  • Measuring voltage: le24V

  • Working conditions Ambient temperature: -20 deg C ~ +55 deg C

  • Humidity: le95% RH

  • Environmental oxygen content: 21%

  • Storage conditions Temperature: -20 deg C ~ +70 deg C

  • Humidity: le70%RH

  • Applications: Household and factory gas leak monitoring devices suitable for detection of liquefied gases, butane, propane, methane, alcohol, hydrogen, fumes, etc.

MQ-3 Sensor
  • Gas: Alcohol (ethanol)

  • Detection range: 10 ~ 1000ppm alcohol

  • Characteristic gas: 125ppm alcohol

  • Sensitivity: R in air/Rin typical gasge5

  • Sensitive body resistance: 1 ~ 20KOmega in air

  • Response time: le10s (70% Response)

  • Recovery time: le30s (70% Response)

  • Heating resistance: 31 Omega plusmn 3 Omega

  • Heating current: le180mA

  • Heating voltage: 5.0V plusmn 0.2V

  • Heating power: le900mW

  • Measuring voltage: le24V

  • Ambient temperature: -20 deg C ~ +55 deg C

  • Humidity: le95% RH

  • Environmental oxygen content: 21%

  • Storage temperature: -20 deg C ~ +70 deg C

  • Storage humidity: le70%RH

MQ-5 Sensor

  • Applicable gases: liquefied gas, methane, gas

  • Detection range: 300 ~ 10000ppm

  • Characteristic gas: 1000ppm isobutane

  • Sensitivity: R in air/R in typical gasge5

  • Sensitive body resistance: 1KOmega~20KOmega in 2000ppm isobutane

  • Response time: le10s

  • Recovery time: le30s

  • Heating resistance: 31 Omega plusmn 3 Omega

  • Heating current: le180mA

  • Heating voltage: 5.0V plusmn 0.2V

  • Heating power: le900mW

  • Measuring voltage: le24V

  • Ambient temperature: -20 deg C ~ +55 deg C

  • Humidity: le95% RH

  • Environmental oxygen content: 21%

  • Storage temperature: -20 deg C ~ +70 deg C

  • Storage humidity: le70%RH

MQ-7 Sensor
  • Product model: MQ-7

  • Product type : Semiconductor gas sensor

  • Detection gas: carbon monoxide

  • Detection concentration: 10-1000ppmCO

  • Loop voltage: le10V DC

  • Heating voltage (VH): 5.0V plusmn 0.2V ACorDC (high)

  • 1.5V plusmn 0.1VACorDC (low)

  • Heating time (TL): 60plusmn1S (high) 90plusmn1S (low)

  • Load resistance (RL): adjustable

  • Heating resistance (RH): 31Omega plusmn 3Omega (room temperature)

  • Heating power consumption (PH): le350mW

  • Sensitive surface resistance (Rs): 2KOmega-20KOmega (in100ppmCO)

  • Sensitivity (S); Rs (in air) / Rs (100ppmCO) ge 5

  • Concentration slope (alpha): le 0.6 (R300ppm/R100ppmCO)

  • Temperature, humidity: 20 deg C plusmn 2 deg C; 65% plusmn 5% RH

  • Standard test circuit: Vc: 5.0V plusmn 0.1V; VH (high): 5.0V plusmn 0.1V; VH (low): 1.5V plusmn 0.1V

  • Warm-up time: no less than 48 hours

MQ135 Sensor
  • Product model: MQ135

  • Product Type: Semiconductor Gas Sensor

  • Detection gas: ammonia, sulfide, benzene vapor

  • Detection concentration: 10-1000ppm (ammonia, toluene, hydrogen)

  • Loop voltage (Vc): le24V DC

  • Heating voltage (VH): 5.0V plusmn 0.2V ACorDC

  • Load resistance (RL): adjustable

  • Heating resistance (RH): 31 Omega plusmn 3 Omega (room temperature)

  • Heating power consumption (PH): le900mW

  • Sensitive surface resistance (Rs): 2KOmega-20KOmega (in 100ppm NH3)

  • Sensitivity (S): Rs (in air) / Rs (100ppm NH3) ge 5

  • Concentration slope (alpha): le 0.6 (R100ppm/R50ppmNH3)

  • Temperature, humidity: 20 deg C plusmn 2 deg C; 65% plusmn 5% RH

  • Standard test circuit: Vc: 5.0V plusmn 0.1V; VH: 5.0V plusmn 0.1V

  • Warm-up time: no less than 48 hours